25. Juli 2018

IAO-IOP2018-Summer Field Study Started

The intensive observation period combined rooftop, roadside and mobile measurements of trace gases, turbulence and radiation.

Innsbruck Atmospheric Observatory

Innsbruck Atmospheric Observatory (IAO) started the summer 2018 intensive observation period. The aims of the study include:

  • quantifing and characterizing urban summertime emissions of various trace gases
  • improving our understanding of the NO-NO2-O3 triad in an urban environment
  • relating flux ratios (NOx/CO2, CO/CO2) above the urban canopy to the respective enhancement ratios at street level

The Following instrumentation is operated at two ground sites:

IAO Rooftop Tower

  • Sonic anemometers (CSAT) at 609m, 614m and 617m elevation [EC]
  • Closed-Path IRGA (EC155) for fast H2O and CO2 mixing ratios at 617m [EC]
  • Inlet of a high flow manifold colocated with CSAT at 617m for the chemical anaysis of trace gases by
    • Two channel NO/NOx monitor (CLD 899 Y; Ecophysics) [EC]
    • Cavity RingDown Spectrometer (CaRDS; Los Gatos)  for direct measurement of NO2 [EC]
    • Chemical Ionization Mass Spectrometry (CIMS) for various volatile organic compounds using a  PTR-Qi-TOF (Ionicon) in H3O+ and NO+ mode [EC]
    • Quantum Cascade Laser (QCL) Spectrometer (Aerodyne Research) for CO, CH4, CO2 and possibly OCS and N2O [EC] operated by Georg Wohlfahrt and Albin Hammerle
    • Fast Ozone Sensor (FOS; Sextant Technology) base on chemiluminenscence of O3 and courmarin [EC]
    • Ozone monitor (APOA260; Horiba) for the continuous calibration of the FOS
  • Remote sensing of NO2, O3,… by DOAS (Pandora; Luftblick) providing  whole atmosphere column as well as near-surface volume concentration products
  • Four component radiation sensor (CNR4) as well as T, rH at 617m

[EC] marks intruments with high sampling rates for eddy covariance capability

IAO Roadside Station

  • Remote sensing of vertical wind profiles by Doppler wind LIDAR
  • Sonic anemometer and IRGA (CPEC) at 577m elevation
  • Inlet of a manifold colocated with CPEC at 577m for the chemical analysis of trace gases by
    • NO/NOx monitor (APNA360, Horiba)
    • CO monitor (APMA360, Horiba)
    • Ozone monitor (ML8810)
  • Four component radiation sensor (CNR4) as well as T, rH at 577m

Beyond these two stations mobile DOAS measurements will be operated from a passenger car along the Inn valley between Schwaz and Kematen by Stefan Schreier.